# Post Battery Control Schedule

> **Preview: not available yet.** This endpoint is documented ahead of its release and currently
answers `501 Not Implemented`. Its contract may still change before release.

Submit battery schedules: per battery, a list of time windows with the battery mode to apply.
Schedules are only accepted for batteries with `flex_trading` enabled in their settings
(see `PATCH /v1/devices/battery/settings`).

`mode` can be set to:


 * `auto` (default): the battery follows its own logic. Pv surplus charges the battery, the battery
covers the house load, the grid covers the rest. The battery returns to `auto` outside your
schedules and whenever NOX Energy takes over.

 * `pause_charge`: the battery does not charge. Pv surplus is exported, the battery can still
discharge.

 * `pause_discharge`: the battery does not discharge. The grid covers the house load, pv surplus
can still charge the battery.

 * `force_charge`: the battery charges at its fixed charge power, from pv first and from the grid
for the rest.

 * `force_discharge`: the battery discharges at its fixed discharge power, to the house first and
to the grid for the rest. Only while the state of charge is above `min_soc_pct`: when it reaches
that limit, NOX Energy takes control and puts the battery in `auto` for the rest of the entry.

Only the modes in the battery's `allowed_modes` are accepted. Outside your time windows the battery
falls back to `auto`. A `force_discharge` entry that starts while the state of charge is already at
or below `min_soc_pct` is accepted, but the battery stays in `auto` until the entry ends.

When you send a new schedule for a battery, it replaces every schedule previously sent for that
battery. You can send schedules for many batteries in one request.



 Timestamp fields in UTC. 

 Time format examples: 
 * 2023-10-01T00:00:00Z
 
 * 2023-10-01T00:00:00 


**NOTE**: 
 * The battery might need some time to react. `start_time` must be at least 1 minute in
the future.



## OpenAPI

````yaml /api-docs/battery/openapi-battery.json post /v1/devices/battery/schedules
openapi: 3.1.0
info:
  title: NOX Energy API - Battery
  description: >
    # Battery API Documentation


    This documentation shows only the endpoints available to battery users.


    **Preview:** these endpoints are documented ahead of their release and
    currently answer

    `501 Not Implemented`.


    ## Authentication


    1. Get your API key from [NOX Energy](mailto:support@nox.energy).

    2. Include the API key in your API calls with the header: `x-api-key:
    YOUR_API_KEY`.


    ## Access Level


    This documentation is specifically for **battery users** who have access to
    these endpoints.


    Base URL: [https://api.nox.energy](https://api.nox.energy)
  version: 1.0.0
servers:
  - url: https://api.nox.energy
    description: Production Server
security:
  - ApiKeyAuth: []
tags:
  - name: Asset Info
    description: API to get basic information about your assets.
  - name: Battery Control
    description: API for battery control specific endpoints.
  - name: User Management
    description: API endpoints to manage users and their data.
paths:
  /v1/devices/battery/schedules:
    post:
      tags:
        - Battery Control
      summary: Post Battery Control Schedule
      description: >-
        **Preview: not available yet.** This endpoint is documented ahead of its
        release and currently

        answers `501 Not Implemented`. Its contract may still change before
        release.


        Submit battery schedules: per battery, a list of time windows with the
        battery mode to apply.

        Schedules are only accepted for batteries with `flex_trading` enabled in
        their settings

        (see `PATCH /v1/devices/battery/settings`).


        `mode` can be set to:


         * `auto` (default): the battery follows its own logic. Pv surplus charges the battery, the battery
        covers the house load, the grid covers the rest. The battery returns to
        `auto` outside your

        schedules and whenever NOX Energy takes over.

         * `pause_charge`: the battery does not charge. Pv surplus is exported, the battery can still
        discharge.

         * `pause_discharge`: the battery does not discharge. The grid covers the house load, pv surplus
        can still charge the battery.

         * `force_charge`: the battery charges at its fixed charge power, from pv first and from the grid
        for the rest.

         * `force_discharge`: the battery discharges at its fixed discharge power, to the house first and
        to the grid for the rest. Only while the state of charge is above
        `min_soc_pct`: when it reaches

        that limit, NOX Energy takes control and puts the battery in `auto` for
        the rest of the entry.


        Only the modes in the battery's `allowed_modes` are accepted. Outside
        your time windows the battery

        falls back to `auto`. A `force_discharge` entry that starts while the
        state of charge is already at

        or below `min_soc_pct` is accepted, but the battery stays in `auto`
        until the entry ends.


        When you send a new schedule for a battery, it replaces every schedule
        previously sent for that

        battery. You can send schedules for many batteries in one request.



         Timestamp fields in UTC. 

         Time format examples: 
         * 2023-10-01T00:00:00Z
         
         * 2023-10-01T00:00:00 


        **NOTE**: 
         * The battery might need some time to react. `start_time` must be at least 1 minute in
        the future.
      operationId: post_battery_control_schedule_v1_devices_battery_schedules_post
      parameters: []
      requestBody:
        required: true
        content:
          application/json:
            schema:
              type: array
              items:
                $ref: '#/components/schemas/DevicesBatteryScheduleRequest'
              title: Request Body
            examples:
              schedule_example:
                summary: Sample battery control schedule
                value:
                  - device_id: e4da3b7f-bbce-4a45-9d2b-1c0e8f7a6b5c
                    schedules:
                      - start_time: '2026-10-17T11:00:00Z'
                        end_time: '2026-10-17T14:00:00Z'
                        mode: pause_charge
                      - start_time: '2026-10-17T18:00:00Z'
                        end_time: '2026-10-17T19:30:00Z'
                        mode: force_discharge
                  - device_id: 1679091c-5a88-4c2f-8e1d-3b2a0f9e8d7c
                    schedules:
                      - start_time: '2026-10-17T02:00:00Z'
                        end_time: '2026-10-17T04:00:00Z'
                        mode: force_charge
      responses:
        '200':
          description: All schedules accepted successfully
          content:
            application/json:
              schema:
                $ref: '#/components/schemas/DevicesBatteryScheduleResponse'
              example:
                rejected: []
                meta:
                  energy_supplier: Energy Supplier A
                  accepted_count: 2
                  rejected_count: 0
        '207':
          description: 'Partial success: some device_ids were rejected'
          content:
            application/json:
              example:
                rejected:
                  - device_id: 1679091c-5a88-4c2f-8e1d-3b2a0f9e8d7c
                    reason: >-
                      The requested mode is not in the allowed_modes of this
                      battery.
                    reason_code: 5
                meta:
                  energy_supplier: Energy Supplier A
                  accepted_count: 1
                  rejected_count: 1
        '400':
          description: Invalid request parameters
          content:
            application/json:
              example:
                detail: >-
                  None of the provided device_ids allow steering or are
                  compatible.
        '403':
          description: Your API key has no access to the battery features
          content:
            application/json:
              example:
                detail: Energy Supplier A is not authorized to access this feature.
        '422':
          description: Validation Error
          content:
            application/json:
              schema:
                $ref: '#/components/schemas/HTTPValidationError'
        '501':
          description: Not implemented yet
          content:
            application/json:
              example:
                detail: This endpoint is not available yet.
components:
  schemas:
    DevicesBatteryScheduleRequest:
      properties:
        device_id:
          type: string
          title: Device Id
          description: Battery device ID the schedule applies to.
        schedules:
          items:
            $ref: '#/components/schemas/BatteryScheduleEntry'
          type: array
          title: Schedules
          description: >-
            Schedule entries for the battery. Replaces any schedule previously
            sent for it.
      type: object
      required:
        - device_id
        - schedules
      title: DevicesBatteryScheduleRequest
    DevicesBatteryScheduleResponse:
      properties:
        rejected:
          items:
            $ref: '#/components/schemas/DevicesBatteryScheduleRejected'
          type: array
          title: Rejected
          description: Devices for which the schedule could not be applied.
        meta:
          $ref: '#/components/schemas/DevicesBatteryScheduleMeta'
      type: object
      required:
        - meta
      title: DevicesBatteryScheduleResponse
    HTTPValidationError:
      properties:
        detail:
          items:
            $ref: '#/components/schemas/ValidationError'
          type: array
          title: Detail
      type: object
      title: HTTPValidationError
    BatteryScheduleEntry:
      properties:
        start_time:
          type: string
          title: Start Time
          description: >-
            Start of the entry in ISO 8601 UTC format. At least 1 minute in the
            future.
        end_time:
          type: string
          title: End Time
          description: >-
            End of the entry in ISO 8601 UTC format. After the end, the battery
            falls back to `auto` unless another entry starts.
        mode:
          $ref: '#/components/schemas/BatteryMode'
          description: >-
            Battery mode to apply during the entry. Must be one of the battery's
            `allowed_modes`.
      type: object
      required:
        - start_time
        - end_time
        - mode
      title: BatteryScheduleEntry
    DevicesBatteryScheduleRejected:
      properties:
        device_id:
          type: string
          title: Device Id
          description: Device ID for which the schedule could not be applied.
        reason:
          $ref: '#/components/schemas/BatteryScheduleRejectedReasons'
          description: Reason why the schedule for the device was rejected.
        reason_code:
          anyOf:
            - type: integer
            - type: 'null'
          title: Reason Code
          description: >-
            Reason code mapping to the reason. {'No battery found for this
            device_id.': 1, 'flex_trading is not enabled in the optimization
            settings of this battery.': 2, 'The device is currently not
            steerable, please check its steerable status.': 3, 'The requested
            mode is not in the allowed_modes of this battery.': 4, 'start_time
            must be at least 1 minute in the future.': 5, 'start_time and
            end_time must be ISO 8601 UTC timestamps with start_time before
            end_time.': 6, 'Schedule entries for the same device overlap.': 7}.
      type: object
      required:
        - device_id
        - reason
      title: DevicesBatteryScheduleRejected
    DevicesBatteryScheduleMeta:
      properties:
        energy_supplier:
          type: string
          title: Energy Supplier
        accepted_count:
          type: integer
          title: Accepted Count
          description: Number of devices that had schedules successfully applied.
        rejected_count:
          type: integer
          title: Rejected Count
          description: Number of device schedules that were rejected.
      type: object
      required:
        - energy_supplier
        - accepted_count
        - rejected_count
      title: DevicesBatteryScheduleMeta
    ValidationError:
      properties:
        loc:
          items:
            anyOf:
              - type: string
              - type: integer
          type: array
          title: Location
        msg:
          type: string
          title: Message
        type:
          type: string
          title: Error Type
      type: object
      required:
        - loc
        - msg
        - type
      title: ValidationError
    BatteryMode:
      type: string
      enum:
        - auto
        - pause_charge
        - pause_discharge
        - force_charge
        - force_discharge
      title: BatteryMode
    BatteryScheduleRejectedReasons:
      type: string
      enum:
        - No battery found for this device_id.
        - >-
          flex_trading is not enabled in the optimization settings of this
          battery.
        - >-
          The device is currently not steerable, please check its steerable
          status.
        - The requested mode is not in the allowed_modes of this battery.
        - start_time must be at least 1 minute in the future.
        - >-
          start_time and end_time must be ISO 8601 UTC timestamps with
          start_time before end_time.
        - Schedule entries for the same device overlap.
      title: BatteryScheduleRejectedReasons
  securitySchemes:
    ApiKeyAuth:
      type: apiKey
      in: header
      name: x-api-key
      description: 'API Key authentication. Enter your API key in the format: YOUR_API_KEY'

````